Simulation Outputs
Nodout is defined for the four accelerometers of the SET, with Node id (NID) and names below.
| NID 50F | NID 50M | Name |
|---|---|---|
| 1000001 | 1019098 | Head_Accelerometer |
| 4052869 | 4057986 | T1_Accelerometer |
| 4052891 | 5036048 | T8_Accelerometer |
| 5031735 | 6000000 | Pelvis_Accelerometer |
The default DATABASE_NODOUT output time interval (dt) is set to 0.1ms.
The FE SET models contain a DATABASE_EXTENT_SSSTAT card, defining the body regions needed to measure the mass distribution of the models (see Model Reference: Measured Mass. The used part sets and names shown in the output ssstat is shown below. The user has to define a DATABASE_SSSTAT_MASS_PROPERTIES card to get the ssstat mass output with a user defined output time interval (dt).
| SETID | Name |
|---|---|
| 100000 | Measure_Head_and_Neck_Mass |
| 300000 | Measure_Arms_Mass |
| 456000 | Measure_Torso_and_Pelvis_Mass |
| 700000 | Measure_Legs_Mass |
Any other outputs have to be defined by the user.
The FE SET models come with color map files (Color_Map_FE-SET-50F and Color_Map_FE-SET-50M) that can be used with LS-PrePost, see figure on main page.